The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A new fault diagnostic parameter, applied to switched reluctance motor drives, is presented. The proposed parameter is a partial average power based on the power converter supply current and the rotor mechanical position information. At high speed operating conditions phase current is not regulated and the machine closed-loop control only needs to observe one current, which is the power converter...
A polar chart of the power converter supply current, comprising phase currents and rotor mechanical position information, is presented, in order to characterize the dynamic operation of a SRM drive. Power converter supply current can be used as additional information of extreme importance when a sensor error or failure occurs. Its analysis is then important and permits to develop appropriate fault...