The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This study describes a method of detection and identification of IGBT-based drive open-circuit faults in direct torque control (DTC) induction motor drives. The detection mechanism is based on wavelet decomposition. The Symlet2 wavelet was selected as the wavelet base to perform stator current analysis during transients. In this method, the stator currents will be used as an input to the system. The...