The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
We present a 87Rb vapor-cell atomic clock using pulsed optical pumping with an optical detection technique. The pulsed optical pumping technique can eliminate the light shifts and increase the stability of vapor-cell atomic clock. For simplicity, direct laser absorption signal is used for the detection of a clock transition. A frequency stability of about 2×10-11 at 1s has been measured and short...