The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Local measurements of the axial mixture velocity and ice fraction profiles were conducted for the vertically, upward adiabatic ice slurry flow in a 0.305-m (W)×0.61-m (L)×0.025-m (gap) rectangular channel using a hot film anemometer (HFA) and an on-line ice slurry sampling/calorimetry technique. Experiments were performed at area-averaged ice fractions and mean velocities up to 16vol% and 0.15ms ...