The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Pressure drop and heat transfer characteristics of different dimple vortex generators arrangement are examined in this study. A total of five heat sinks were made and tested, including plain fin, dimple, two-group dimple, oblique dimple gap 4-12 fin, oblique dimple gap 6-12 fin. The tested results indicate that the pressure drop for dimple fin geometry is significantly higher than other fin types,...