The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Two mass erosion mechanisms or mass loss modes for electrodes during the repetitive arcing processes should be responsible for the failure of electromagnetic relays, and there are evaporation erosion and sputter erosion. Of these two, the evaporation erosion is believed to be the main failure mechanism for the electrodes used in low-current relays. Unfortunately, there is still no straight-forward...
The break arc simulation model for aerospace relay is built based on the magneto-hydrodynamics (MHD) theory. The contact erosion is considered and the electrical conductivey of the plasma sheath in the arc root region is equalized in this model. The static arc characeristics with silver vaper and nitrigen are acquired with the computational fluid dynamics (CFD) software FLUENT. The effect of the silver...