The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
An effort was undertaken to improve the current cycle performance of the diffusion-absorption refrigerator (DAR). The thermodynamic basis for the design changes is to reuse waste heat from the rectifier to heat the weak absorbent from the absorber. A new generator with heat exchanger (GWHX) was designed and fabricated. The test results of the DAR with GWHX are compared with baseline tests. The...