The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
With the growth of aging populations in both developed and developing countries and the increase of noncommunicable disease, the contradiction between increasing healthcare demands and the shortage of medical specialists have become more and more serious. Wearable personal health devices (PHDs) provide a good solution to this problem. But due to the proprietary interface and data protocol, the compatibility...
With aim of reducing the incidence of false critical arrhythmia alarms in intensive care units, a novel data fusion and machine learning algorithm is presented in this article. The 2015 PhysioNet/Computing in Cardiology Challenge database was used in this present algorithm, with each grouped as an asystole (AS), extreme bradycardia (EB), extreme tachycardia (ET), ventricular tachycardia (VT) or ventricular...
Due to the sporadic occurrence of cardiovascular disease, long term continuous monitoring is needed. An embedded wireless health monitoring system is designed and implemented, which is made up of wearable monitoring nodes with Bluetooth Low Energy (BLE) wireless transmission, a sensor data gateway and smart terminal etc. The wearable monitoring nodes are integrated electrocardiography (ECG) and impedance...
A multifunction wearable noninvasive ambulatory monitoring sensor based on Electrocardiogram (ECG) and Impedance Cardiography (ICG) has been designed, fabricated and tested. The electric function (with ECG) and mechanical function (with ICG) of the heart can be monitored simultaneously and continuously. Based the RR serials computed from ECG waveform, the sympathetic and parasympathetic function of...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.