The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents an algorithm for locating faults on series-compensated transmission lines. The algorithm suits to both single- and double-circuit series-compensated lines. Use of two-end synchronized measurements of currents accomplished by current differential protective relays with additional incorporation of the locally measured three-phase voltage is considered. More superior solution with...
This paper is focused on optimizing the distance protection algorithm for series-compensated line. This algorithm requires estimation of three-phase voltage drops across capacitors bank. For this purpose a nonlinear differential equation is solved on-line, applying comparatively low sampling frequency. In order to assure high fidelity of the waveforms reconstruction using the up resampling procedure...
An accurate algorithm for locating faults on a series-compensated line is presented. This algorithm can be applied with current differential protective relays since two-end currents and one-end voltage are utilized as the fault locator input signals. The algorithm applies two subroutines and the procedure for indicating the valid subroutine. The algorithm has been evaluated using the fault data of...
A new algorithm designated for locating faults on a double-circuit line is presented. It is assumed that the fault location function is incorporated into the current differential relay at the particular line end. Besides three-phase currents measured synchronously at both line ends, which are utilized by the protective relays, the fault locator is supplied with three-phase voltage from the local line...
An accurate fault location algorithm for double-circuit series compensated lines is presented. Use of two-end unsynchronized measurements of current and voltage signals is considered. The algorithm applies two subroutines, designated for locating faults on particular line sections, and additionally the procedure for selecting the valid subroutine. The subroutines are formulated with use of the generalized...
The paper presents an adaptive procedure for digital distance protection device that allows to compensate for the negative influence of the reactance effect, caused by fault resistance and pre-fault power flow. The procedure utilizes locally measured phase currents and voltages and has been designed to operate with double-circuit power lines. The algorithm calculates on-line shift vector components...