The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In order to validate the accuracy levels of three forms of transfer function models (TFMs), dynamic thermal performance tests of a flat-plate solar air collector with louvered fin structure are conducted. Model coefficients in the TFMs are constructed by strict error analysis and the weighed least square (WLS) method. Comparing with the experimental data, it is verified that the three forms of TFMs...
The existing second-order transfer function models (TFMs) for solar collector dynamic tests are reviewed in light of the heat transfer principles, their inherent relationship, and limitations. Then, another form of TFM in terms of the collector heat removal factor FR is put forward in this study. And the equivalent relationships among different forms of TFMs are elucidated. Strict error analysis and...