The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Generally additional leakage inductance and two clamp diodes are adopted into the conventional phase shift full bridge (PSFB) converter for reducing the voltage stress of secondary rectifier diodes and extending the range of zero voltage switching (ZVS) operation. However, the core and copper loss caused by additional leakage inductor can be high enough to decrease the whole efficiency of DC/DC converter...
Conduction loss reduction technique using a small resonant capacitor for a phase shift full bridge converter with clamp diodes is proposed in this paper. The proposed technique can be implemented simply by adding a small resonant capacitor beside the leakage inductor of transformer. Since the voltage across the small resonant capacitor is applied to the small leakage inductor of transformer during...