The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The introduction of solids into liquid insulation located between two conductors is often necessary to provide mechanical support in sub-systems of high-voltage, pulsed-power machines. Flashover on or around the surface of the solid can result in permanent damage to the insulation system, resulting in reduced operational voltages and system downtime as the damaged component is located and replaced...
Surface discharges along oil-immersed solids used as insulators and supports in high-voltage pulsed-power equipment can lead to catastrophic system failures. To achieve reliable compact pulsed-power systems, it is important to quantify the electrical fields at which surface flashover, or other types of breakdown event, will occur for different dielectric materials. This paper reports the observed...