The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Przedstawiono wyniki badań mikrostruktury stali X10CrMoVNb9-1 (T91) po około 105 000 godzin eksploatacji w temperaturze 540°C. Próbki do badań pobrane zostały z wężownicy przegrzewacza pary. Po eksploatacji badaną stal charakteryzowała listwowa budowa odpuszczonego martenzytu z stosunkową dużą gęstością dyslokacji oraz licznymi wydzieleniami. Długotrwała eksploatacja przyczyniła się głównie do wydzielenia...
Przedmiotem badań były złącza doczołowe rur ze stali X13CrMoCoVNbNB9-2-1 (PB2) o średnicy zewnętrznej 219,1 mm i grubości ścianek 31 mm. Złącza były spawane konwencjonalnie tj. z obróbką cieplną po spawaniu oraz bez obróbki cieplnej, z użyciem techniki ściegów odpuszczających. Ściegi graniowe spawano metodą TIG (Tungsten Inert Gas) (141), a ściegi wypełniające oraz lica spawano ręcznie elektrodami...