The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Increasing requirement of traveling-wave tubes (TWTs) with miniature size, less weight, high efficiency, high power, etc increases complexity of TWT packaging for thermal modeling. Two-third of the total power consumption of a typical TWT is dissipated in the collector. The rise in temperature due to the dissipated power in the collector has to be drained out efficiently without creating any hot spots...
Non-conventional 3-stage collector geometry has been designed using EGUN code for high efficiency applications deviating from typical 4-stage depressed collector. Efficiency of this collector is very much similar to 4-stage collector with reduced dimensions, weight, etc, which are very important if such collector is to be used for space applications. Such collector also reduces the complexity of electronic...