The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Purpose In the field-in-field (FIF) technique in breast tangential radiotherapy, the energy of the subfield is usually the same as the energy of the main field. However, some studies have applied 10–18 MV to subfields in patients with large breasts. We compared two FIF plans in 66 breast cancer patients: in one, the energy of the subfield was the same as that of the main field (the mono energy plan);...