The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
There is a novel method for creating a 2-d parameterized finite element model of the human femur with matching artificial hip joint based on X-ray image before the hip joint replacement surgery. It can help us to evaluate the selected appropriate hip joint prosthesis
A standardized and modularized finite element model of a normal human skull is established to simulate the unilateral defective pattern of the maxillary and the stress distribution of craniofacial skeleton with repair subject to the bite force. Based on the model, the stress evaluation of autologous bone grafted and zygomatic implant is to optimize the repairing method, and to rebuild the occlusal...
Standard medical implants are used in most implantation cases, but in some special cases, only those implants conforming to individual patient's skeletal morphology can serve the purpose. This paper proposes a new approach to design and fabricate customized exact-fit medical implants. With a real surgical case as the example, technical design details are presented; and two algorithms are given respectively...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.