The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
For evaluating the anti-impact ability of vessel electric station, the numerical simulation of air explosion to entire structure was done by fluid-structure coupling algorithm in LS-DYNA software. Non-contact explosive load was added omni directionally by sphere loading method. Based on simulating results, the weakness position was founded and the structure dynamic response curves were created. Furthermore...
It is a hot topic that how to calculate equipment response of non-contact explosive impact. Through theoretical analyzing the problem of some expertpsilas research about shock wave, and studying non-linear FE software LS-DYNA and AUTODYN in depth, the paper put forward a method to analyze impact response of equipment by using LS-DYNA and AUTODYN software. The paper used LS-DYNA load sub function to...