The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In this paper, effects of geometrical configuration on AC loss characteristics of cable conductors assembled by multiple YBCO tape in polygonal arrangement were numerically studied. The previously developed numerical model was modified to analyze the AC loss in the HTS tape in the polygonally assembled multi-layer cable. By using the numerical model, the influences of the cable geometrical parameters,...