The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents a rigorous model to simultaneously solving the mechanic and electromagnetic coupled differential equations which govern the dynamic response of the contactor. The model is validated with data obtained experimentally and therefore the accuracy of the model is validated. On the other hand, an estimator of the position and the velocity of the contacts, as well as of the moving core...
This paper describes a novel algorithm for a closed-loop sensorless control of electromagnetic devices. It integrates a novel fault diagnosis algorithm of the whole electromagnetic circuit. Applied to a contactor with a dc core, it eliminates the armature and contact bounce, whether it is ac or dc powered and at either 50 or 60 Hz. The position and velocity of the moving armature and contacts are...