The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
To drive SiC power module with high-speed switching, the stray inductance becomes a key factor in converter design. In this work, the stray inductances of module and peripheral circuits are investigated by simulation and measurement. With the loop stray inductance of 29.2 nH, the module is tested up to 800 V and 50 A with insignificant EMI issues of ringing and overshoot. And the dv/dt ratios at turn-off...