The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Experiments have been performed testing magnetic priming at the cathode of a relativistic magnetron to study the effects on high power microwave performance. Magnetic perturbations were imposed utilizing three, high-permeability nickel-iron wires embedded beneath the emission region of a 1.27 cm diameter cathode, spaced 120 degrees apart (for N/2 symmetry in an N (6) cavity magnetron). These three,...
Experiments have been performed in testing magnetic priming at the cathode of a relativistic magnetron to study the effects on high-power microwave performance. Magnetic priming consists of N/2 azimuthal magnetic perturbations applied to an N-cavity magnetron for rapid generation of the desired number of electron spokes for the pi-mode. Magnetic perturbations were imposed by utilizing three high-permeability...
Magnetic priming experiments on the UM/ L-3-Titan relativistic magnetron (100 MW in L-band, -300 kV, ~3 kGauss), have shown suppression of unwanted modes and major reduction in starting currents for the pi-mode. Data from continuing experiments on magnetic priming at the cathode will be presented, as well as preliminary data on magnetic priming at the cathode and anode. Azimuthally-varying, axial-magnetic-perturbations...
Magnetic priming consists of N/2 azimuthal perturbations applied to the axial magnetic field in an N-cavity magnetron. When employed on the UM/L-3-Titan, 6-cavity, relativistic magnetron (L-band, -300 kV, ~3 kGauss), magnetic priming has shown enhanced performance over uniform-B- field operation. Magnetic perturbations are imposed utilizing Mu-metal wires embedded in either the cathode or both the...
Magnetic priming [1] experiments performed on the UM/Titan relativistic magnetron (6-vane, -300kV, 5-10kA, 0.3-0.5 mus) have shown improvements in magnetron performance over baseline operation. In the current experimental setup, three, 4-cm long magnetic wires (Mu-Metal) are located within the cathode structure, centered beneath the emission region, and spaced 120 degrees apart. These wires produce...
In order to study the effectiveness of this magnetic priming structure, magnetic field data, modeled from the field precision magnum magnetostatics codes, were imported into 3-D MAGIC PIC and run for the relativistic magnetron. Simulations showed faster startup and enhanced pi-mode control compared to the unprimed baseline
Summary form only given. Research is underway to investigate radio frequency (RF) priming of relativistic magnetrons for rapid startup and reduced mode competition. Experiments utilize the MELBA-C to drive the Titan 6-vane relativistic magnetron at parameters: V=-300 kV, I=1-10 kA, e-beam pulselength=0.5 musec, microwave power=100-500 MW, microwave frequency=1-1.3 GHz (with tuning). MELBA-C's ceramic...
Summary form only given. Experiments have been performed on a relativistic magnetron using innovative monolithic metal cathodes (Al). These new types of cathodes are fabricated utilizing KrF laser ablation of metal surfaces to enhance the local E field. Two new types of cathodes invented are: projection ablation lithography (PAL) and ablation line focused (ALF) cathodes. PAL cathodes are fabricated...
Summary form only given. Research is underway to develop a viable technique to implement magnetic priming in the UM/Titan relativistic magnetron (-300 kV, 5-10 kA, 0.3-0.5 mus) for rapid startup and mode control. Magnetic priming involves imposing N/2 azimuthal variations in the axial magnetic field of an N-vane magnetron operating in the pi-mode. This type of magnetic priming has been demonstrated...
Physics International reports the results of a three-phase program to explore the feasibility of constructing and operating a large array of high power, phase-locked vircators. The approach has been to study multiple high power sources in all the relative configurations that would be encountered in an array architecture. Resonant cavities enclosing the virtual cathodes reduce the bandwidth of the...
Summary form only given, as follows. Phase locking of a vircator array driven by a relativistic magnetron in a pure master-slave configuration has been achieved. A single high-voltage pulse drives the relativistic magnetron and the vircator array in series. Phase locking occurs for ~40 ns. The time required to lock is ≃10 ns. The peak array power is ≃1 GW. The injection ratio, ρ,...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.