The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The deep foundation fit of Xin Ming He building was reinforced by soil nail, shot concrete and steel bar mesh, and the calculated pressure per unit area of soil nail is about 83.48kN which is larger than the largest lateral earth pressure which is about 59.55kN, from which it can be known that the foundation fit is stable. Meanwhile, the 3D-σ finite element program was used to simulate axial force...