The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Because of loss of cross-sectional area of pipes and ropes caused by corrosion and mechanical damage, the maximum stress and structural strength of material will be greatly reduced. In order to avoid structural failure, it is important to intelligently measure the loss rate of cross-sectional area of material. The traditional methods of measuring the residual material thickness are based on contact...
As a rapid, noncontact, and nondestructive technology, magnetostrictive guided waves have been widely used for the quality inspection of pipes and stay cables. Traditionally, a single-frequency signal with a high amplitude and a long pulse duration is used to increase the excitation energy and detection distance. However, the longer the pulse duration of a single-frequency signal is, the lower the...