The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The application of phasor measurement unit (PMU) measurements and adaptive wide-area damping control based on federated Kalman filters are investigated. The Kalman filters used for estimating the operating conditions are federated using chi-square variables and a confidence interval. When the power system is operating precisely at a preselected operating point, only the corresponding controller is...
The application of PMU measurements and perfect regulation with robust control to damp inter-area oscillations is investigated. Combined with the robust control theory, a perfect regulation control with robust performance is obtained. The closed loop eigenvalues are gradually increasing from the under damping or negative damping to positive damping. A 4-machine 13-bus study system reinforced is considered...
This paper deals with the robust control problem for damping power system low-frequency oscillations considering the uncertainties. In the process of designing the damp controller, uncertain parameters are introduced into perturbation matrix, meanwhile, both the H∞ disturbance depression and the optimal H2 performances of the closed-loop control system are satisfied simultaneously for all allowable...
The application of PMU measurements and collocated control to damp inter-area oscillations with coordinated DC lines and static var compensators (SVCs) is investigated. The closed loop eigenvalues are excluded from a region of the complex plane guaranteeing that low frequency modes must be damped. A 16-machine, 68-bus study system reinforced with four DC lines or two DC lines and two SVCs is considered...
This paper develops a systematic procedure of designing global power system stabilizers (GPSSs) based on collocated control to enhance the damping during interarea oscillations. The availability of remote signals from phasor measurement units (PMUs) enables the wide-area control in large scale systems. The closed loop eigenvalues are excluded from a region of the complex plane by the collocated control...