The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In this paper, we provide further evidence of the reliability of a lumped parameter urban canopy model coupled with an EnergyPlus building energy model to estimate urban temperatures. In a previous paper, we presented a preliminary validation of the model using data measured at Masdar Institute, Abu Dhabi, United Arab Emirates. At present, we conduct a more comprehensive validation based on BUBBLE...
In this paper, we describe a lumped thermal parameter model coupled with an EnergyPlus model used for estimating temperature and specific humidity in the near-surface urban environment. Estimations made by the model are compared to measurements obtained from data loggers installed in an urban canyon of Masdar Institute (Abu Dhabi). Based on these comparisons, we first evaluate the most likely ratios...