The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Five large-scale fire tests, including one pool fire test and four HGV mock-up fire tests, were carried out in the Runehamar tunnel in Norway in year 2003. New data and new analyzes are presented in this paper, together with a short summary of previous work on these tests. Heat release rate (HRR), radiation, fire spread, gas production, backside wall temperature, visibility, backlayering, fire growth...