The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
We carried out a set of experiments on the direct-contact condensation of atmospheric steam for subcooled water flowing co-currently and counter-currently in a circular pipe. The condensation heat transfer coefficient was evaluated both for co-current and counter-current steam–water flow cases in a horizontal circular pipe. In the current experiment the dependency of the liquid Nusselt number on the...