The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Summary form only given. A high voltage resonant pulser is designed by using an air core transformer. Triple resonant circuit is used to step up the primary voltage. The voltage step-up ratio is designed as about eleven at the charging stage. A distributed PFN is used to form a squre waveform. The output has an overvolted sparkgap switch that transfers energy to a matched resistive load with the PFN...
It is beneficial to use a resonant pulse transformer charging circuit for designing of a high voltage generator. A high voltage triple resonant generator is designed. A high voltage air core transformer is used in the circuit. Triple resonant charging circuit with the transformer is used to step up the primary voltage. The voltage step-up ratio is designed as about eleven at the charging stage. A...
The structure of an air-core cylindrical high voltage pulse transformer is relatively simple, but considerable attention is needed to prevent breakdown between transformer windings. Since the thickness of the spiral windings is on the order of sub-millimeter, field enhancement at the edges of the windings is very high. Therefore, it is important to have proper electrical insulations to prevent breakdown...
Cylindrical type air core pulse transformers capable of passing high voltage and energy pulse waveforms with high efficiency and low distortion require a much more delicate design balance of physical dimensions and electrical parameters than iron or ferrite core units. The structure of an air core high voltage pulse transformer is relatively simple, but considerable attention is needed to prevent...