The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Natural gas pressure has to be reduced from medium pressure of 1.724 MPa (250 psia) to lower pressure of 0.414 MPa (60 psia) at Town Border pressure reduction Station (TBS). Currently, the pressure reduction is carried out by throttling valves while considerable amount of pressure energy is wasted. One of the equipment which could be used to recover this waste energy is the reciprocating expansion...