The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Sucker Rod Pump is a prevalent industrial solution in artificial lift applications in oil industries. Linear motors are becoming more popular as they are applied in new applications in various fields. Linear motors may be employed in artificial lift systems by placing a linear motor downhole to drive the reciprocating pump directly. This system is intended to extend the application of reciprocating...
Back-EMF self-sensing is commonly used in induction machine (IM) drive systems. Deadbeat-direct torque and flux control (DB-DTFC) has also shown to be a highly effective method for IM control. At low speeds, accurate machine parameters are important for both DB-DTFC and back-EMF self-sensing performance. In this paper, an injection-based real-time parameter estimation method in IM DB-DTFC drives for...
This paper introduces an enhanced speed self-sensing method that tracks stator flux linkage in electric machines at very low speeds. Volt-second sensing technology is used to mitigate the inverter nonlinearity, which is the major source of flux estimation error in the very low speed range. By integrating volt-second sensing in the Gopinath style closed-loop flux observer, the rotor speed information...
For a converter using the digital processor for control system, the digital time delay is a main reason to reduce the system bandwidth, leading to a relatively slow dynamic or even unstable operation. To alleviate the negative impacts of digital delays, numerous time delay compensation methods have been developed, of which the model-free schemes are independent to model accuracy whereas the model-based...
This work proposes and investigates a renewable energy distributed generation system involving a matrix converter with an output filter working as a stable voltage supply. This is especially relevant for the stand-alone operation of a renewable energy microgrid where a stable sinusoidal voltage with prescribed amplitude and frequency under various load conditions is the main control objective. A controllable...
This paper presents a grid-side current controller for grid-tied inverters with LCL filter, including harmonic current elimination. Contrarily to previously proposed harmonic-current controllers, the presented solution offers a generalized method that gives a consistent and stable performance irrespectively of the number of current harmonics to be canceled and of the resonant frequency of the LCL...
Permanent magnet synchronous machines (PMSMs) have been used in many applications due to their outstanding advantages such as high torque/power density, high efficiency, light weight and good reliability. However the emerging field of electrical traction gave arise to issues which were in general hardly considered in the past Yet, even though well established methods for eDrive control are available,...
Linear Electric Submersible Pump is a new industrial solution in artificial lift applications. Linear motors are placed downhole to drive the reciprocating pump directly. This system is intended to overcome some of the sucker rod pump limitations. The new configuration will allow implementation in deviated and off-shore oil wells. Integrated Drive-Motor technology shows many promising advantages....
This paper presents a robust deadbeat predictive power control (DBPC) for PWM rectifiers with consideration of parameter mismatches. To achieve accurate power control with crude estimations of the grid-side impedance, the system disturbance caused by inaccurate parameter is analyzed. Then, a complex power based sliding-mode disturbance observer (SMDO) is proposed. Both DBPC and SMDO are implemented...
This paper aims to present a model-based design implementation of deadbeat-direct torque and flux control (DB-DTFC) with back-EMF self-sensing for a SPMSM using rapid control prototyping (RCP) in a real-time control environment. Current and flux observers are key technologies for achieving DB-DTFC. However, the implementation of DB-DTFC using RCP tools can lead to an incorrect execution sequence and...
Despite distinctive advantages such as fast dynamic, simple concept and ease of implementation, model predictive direct power control (MPDPC) suffers from some major drawbacks. First, in order to provide sinusoidal currents and low-ripple powers, very high sampling rates are required for MPDPC implementation. Furthermore, this method requires accurate knowledge of system parameters and its performance...
Brushless doubly-fed induction generator (BDFIG) is a new type of ac induction machine and can be used for both grid-connected and stand-alone power generation. The conventional control methods for the BDFIG almost all rely on the encoder, which brings many limitations in terms of cost, complexity, reliability, and so on. This paper presents a new rotor speed observer (RSO) for the encoderless operation...
This paper proposes an approach to estimate the ratio between shorted and total turns in interior permanent magnet synchronous machines (IPMSM). When an inter-turn short circuit (ISC) occurs, a particular disturbance affects the motor. The proposed method estimates this disturbance using an observer; this estimated signal is used to obtain the short circuit ratio. The observers are based on a dynamic...
The state of charge (SOC) of Lithium-ion batteries is one of the most critical indexes for battery management system (BMS) in electric vehicles (EV) and hybrid electric vehicles (HEV). To improve SOC estimation performance and reduce chattering effect caused by conventional sliding mode observer (SMO), a novel sliding mode observer is presented in this paper. The switching gains of the proposed observer...
The accurate and fast detection of the grid voltage attributes (e.g. frequency and amplitude) are gaining more attention in microgrids due to the new stringent amendments to the microgrid standards. In this paper, two novel observer based techniques are introduced; one for estimating the frequency and another for the amplitude of the grid voltage. The proposed observer techniques offer superior performance...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.