The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Analysis of two-level and three-level front-end boost-converter employing current error space phasor based hysteresis controller is presented in this paper for various line-side and load-side conditions. Due to the coordination between all the three-phases and selecting only adjacent voltage vectors, the proposed controller is able to overcome limitations of conventional hysteresis current controller;...
Medium voltage power conversion is increasingly being preferred as the technology of choice for large offshore wind turbines. This is primarily due to the reduced current rating as the voltage rating is increased, allowing sizeable reductions in cable cost and weight. With the application of low speed permanent magnet machines in wind turbines the main cause of mechanical failure, the gear box may...