The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Nursing facility residents at high risk for pressure ulcers are turned in bed by staff at regular intervals. In an ongoing large, multi-site randomized clinical trial (RCT) the impacts of 2, 3, and 4 hour turning intervals are being studied on pressure ulcer outcomes. In the RCT, it is necessary to objectively confirm the reported times of assisted turning by certified nurse assistants using activity...
We present a novel force sensor for the injection of both suspended and adherent cells. Unlike most configurations, this force sensor is independent of the tool interacting with the cells. It is a planar structure that provides a surface sensitive to out-of-plane forces where living cells can be placed for manipulation. It also integrates two beam resonators. Forces perpendicular to the sensor's plane...
Cardiac auscultation has proven to be an excellent diagnostic tool. Heart sound processing algorithms are not completely robust in the presence of noise, requiring clean segments of heart sounds to extract reliable diagnostic features. This paper presents a new approach to detect transient noises mixed with heart sound. The algorithm explores a single channel source separation algorithm and evaluates...
The effect of increasing the number of scans in the “cluster” of an interleaved silent steady state (ISSS) fMRI imaging scheme from 1 to 2, and then to 3 was examined by a fixed-effects analysis of an auditory short-term memory task with four subjects. Compared to a cluster size of 1, a cluster of 2 scans improved sensitivity at detecting brain activity and statistical power, while a cluster of 3...
In this study, an electromagnetics-based inverse sensitivity mapping method is introduced for applications in high field MRI. Instead of using simplistic numerical approximations, the sensitivity of the radio-frequency coil was determined through a field approach by using iterative optimization. The current study is an extension to previous studies on the inverse method, which has restricted itself...
This paper presents the analysis of the autonomic nervous system (ANS) control and cardiac baroreflex sensitivity in patients undergoing general anesthesia for major surgery, with the goal of evaluating the effects of anesthesia bolus induction with propofol on autonomic control of heart rate (HR) and arterial blood pressure (ABP). The increase in baroreflex gain in the LF band observed through two...
Doxifluridine, a prodrug of 5-fluorouracil (5-FU), was used as the initiator directly in ring-opening polymerization of ε-caprolactone to form hydrophobic doxifluridine-poly(ε-caprolactone) (doxifluridine-PCL) that was further grafted with hydrophilic chitosan to synthsize amphiphilic doxifluridine-PCL-chitosan copolymer. This amphiphilic copolymer was self-assembled into micellar nanoparticles. After...
In this contribution the evaluation of a system called “Eventlogger” is presented, which is installed in a day hospital for old age psychiatry. The Eventlogger is a radio based module with an adjustable communication range, able to recognize interaction of the user with objects or with other people. It is intended to function as a monitoring tool for the users' activities. Due to the demographic change...
The reduction of the number of EEG features to give as inputs to epilepsy seizure predictors is a needed step towards the development of a transportable device for real-time warning. This paper presents a comparative study of three feature selection methods, based on Support Vector Machines. Minimum-Redundancy Maximum-Relevance, Recursive Feature Elimination, Genetic Algorithms, show that, for three...
We have developed a range of vision rehabilitation devices and techniques for people with impaired vision due to either central vision loss or severely restricted peripheral visual field. We have conducted evaluation studies with patients to test the utilities of these techniques in an effort to document their advantages as well as their limitations. Here we describe our work on a visual field expander...
Advancement in wireless health sensor systems has triggered rapidly expanding research in continuous activity monitoring for chronic disease management or promotion and assessment of physical rehabilitation. Wireless motion sensing is increasingly important in treatments where remote collection of sensor measurements can provide an in-field objective evaluation of physical activity patterns. The well-known...
Since the 1970s, various automatic sleep spindles procedures have been implemented and presented in the literature. Unfortunately, their results are not easily comparable because the databases, the assessment methods and the terminologies employed are often radically different. In this study, we propose a systematic assessment method for any automatic sleep spindles detection algorithm. We apply this...
A physiological control system was developed for a rotary left ventricular assist device (LVAD) in which the target pump flow rate (LVADQ) was set as a function of left atrial pressure (LAP), mimicking the Frank-Starling mechanism. The control strategy was implemented using linear PID control and was evaluated in a pulsatile mock circulation loop using a prototyped centrifugal pump by varying pulmonary...
The characterization of visual field loss provides a valuable diagnostic metric for studying the effects of damage to the retina, optic nerve or visual cortex. We describe a tool, the Quadrant Vision Perimeter (QVp), to rapidly and accurately measure visual fields. In addition to measuring the location of visual deficits, the tool can assess modality-specific field loss (e.g., impaired detection of...
A new, automated way to obtain signatures of active motor units (MUs) from high density surface EMG recordings during voluntary contractions is presented. It relies on clustering of repetitive shapes corresponding to different MU action potentials (MUAPs) present. The number of clusters and the mean shapes of the MUAPs as observed on the electrode grid, are estimated in a fast way without user interaction...
The earliest signs of Retinopathy of Prematurity (ROP) are tortuosity and dilation of retinal vessels. Such vascular changes are considered of primary importance for the diagnosis and the follow-up of the disease. However, a widely accepted computerized system for their quantitative measurement is still missing. Images taken from a preterm baby's eye are often low-contrast, noisy, and blurred. Algorithms...
This abstract presents new results on the structure and function of vestibular part of the inner ear of vertebrates with special emphasis on human behavior. First we summarize a mathematical analysis of motion of the endolymphatic fluid, justifying known approximated formulas for the cupula functioning based on a set of anatomical parameters. Some of these parameters can be estimated from the bony...
Heart rate variability (HRV) may provide anesthesiologists with a noninvasive tool for monitoring nociception during general anesthesia. A novel wavelet transform cardiores-piratory coherence (WTCRC) algorithm has been developed to calculate estimates of the linear coupling between heart rate and respiration. WTCRC values range from 1 (high coherence, no nociception) to 0 (low coherence, strong nociception)...
Hypoglycemia is the most acute and common complication of Type 1 diabetes and is a limiting factor in a glycemic management of diabetes. In this paper, two main contributions are presented; firstly, ventricular repolarization variabilities are introduced for hypoglycemia detection, and secondly, a swarm-based support vector machine (SVM) algorithm with the inputs of the repolarization variabilities...
Mock circulation loops (MCLs) are used to evaluate cardiovascular devices prior to in-vivo trials; however they lack the vital autoregulatory responses that occur in humans. This study aimed to develop and implement a left and right ventricular Frank-Starling response in a MCL. A proportional controller based on ventricular end diastolic volume was used to control the driving pressure of the MCL's...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.