The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The purpose of this study was to examine the potential of diffusion-weighted (DW) three-dimensional (3D) MP-RAGE MRI for diffusion-tensor mapping of the rat brain in vivo. A DW-3D-MP-RAGE (3D-DWI) sequence was implemented at 2.0 T using six gradient orientations and a b value of 1000 s/mm 2 . In this sequence, the preparation sequence with a “90°RF-motion proving gradient (MPG): MPG-180°RF–MPG-90°RF”...
Proton magnetic resonance spectroscopic imaging (MRSI) and diffusion-weighted imaging (DWI) were carried out in men with increased prostate-specific antigen (PSA) level. Forty subjects [controls (Group I) and patients (Groups II and III with PSA >20 and 4–20 ng/ml, respectively)] were investigated using endorectal coil at 1.5 T prior to transrectal ultrasound (TRUS)-guided biopsy. Metabolite ratio...