The aim of the present study is to show the optimum design procedure of welded aluminium structural components subject to fluctuating forces in addition to permanent static loads. Four illustrative numerical examples are given: a square hollow section (SHS) compressed strut connected to gusset plates, a circular hollow section (CHS) compressed strut with a welded splice, a cantilever I-beam with fillet welded connection to a column and a box beam with welded inside diaphragms. In the case of a SHS strut cyclically loaded by tension-compression and welded to gusset plates, the optimum width and thickness can be calculated considering the fatigue and local buckling constraints. The fatigue stress range of welded aluminium joints is determined according to BS 8118. A CHS strut with a welded splice is designed for fatigue stress range of toe cracking of the connecting fillet welds and the required weld size is determined on the basis of root cracking. Similar design aspects are applied to the optimum design of a welded I-section cantilever beam.Le but de cette etude est de montrer la methode optimale de calcul d'elements de structure en aluminium soumis a des sollicitations variables se superposant aux sollicitations statiques. Quatre exemples de calcul sont donnes: profiles creux de section carree (SHS) assembles a des goussets, profiles creux de section circulaire (CHS) avec raccords soudes, poutre en I en console avec des diaphragmes internes soudes. Dans le cas des profiles SHS, sollicites de facon cyclique en tension/compression et soudes a des goussets, la largeur et l'epaisseur optimales doivent etre calculees en considerant la fatigue et le flambage local. Les contraintes en fatigue des joints soudes en aluminium sont determinees selon le BS 8118. Un profiles CHS avec raccord soude est calcule en fatigue en fonction de la fissuration au raccordement des soudures d'angle de liaison et les dimensions des soudures requises sont determinees sur la base de la fissuration a la racine. Les memes concepts de calcul sont appliques pour la conception optimale de poutres en I en console.