The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Super 304H, HR3C and Sanicro 25 grade austenitic matrix steels are used in the construction of pressure components of boilers with supercritical operating parameters. The article presents the results of microstructure examination in delivery condition and after ageing for up to 50,000 hours at 700°C. The microstructure examination was performed using scanning and transmission electron microscopy....