The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Several processes have been initiated for the development of technical concepts, guidelines and common requirements of HVDC Grid Systems. For implementing extended HVDC Grid Systems on a multi-vendor basis consolidated and agreed functional requirements for equipment and solutions are needed. Providing such requirements is the role of international standardisation bodies. With the primary focus on...
In the coming years an increasing quantity of vacuum interrupters (VI) is expected to reach the end of its service life. Leading manufacturers can provide a service life of up to 30 years due to high quality standards and sophisticated production processes. However, their operating performance observed so far indicates the possibility to extend this service life, in case of non-intrusive diagnosis...
The magnetron method is well established for the internal pressure measurement of vacuum interrupters. Its application during the manufacturing process is essential for the determination of the vacuum quality. The evaluation of the magnetron measurement requires precise knowledge of the residual gas composition and the influence of the metallic surfaces in the vacuum interrupter due to gas binding...
The maintenance of high voltage gas circuit breakers requires high personal as well as monetary efforts for the asset operator. Furthermore, a faulty reassembly of a circuit breaker during maintenance can lead to a circuit breaker failure during operation. One possibility to reduce those efforts as well as the failure risk is the application of non-invasive diagnostic techniques. This research work...
In standard high voltage gas circuit breakers -important safety elements in today's power grids-, a small surface layer of polytetrafluoroethylene (PTFE) vaporizes at the high temperatures occurring in the arcing zone during the high current phase of the interruption process. This ablation continues even some hundred microseconds after the arc has been quenched and it actually changes the total gas...