The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents an experimental investigation on transformer oil subject to impulse voltage. The dynamic impedance of the mineral oil samples was determined from the instantaneous ratio of voltage and current characteristics at the instant of breakdown. A dedicated test cell was constructed to contain the insulating oil. A sphere-sphere electrodes gap of variable length was used for the experiments...
The risk of breakdown in mineral insulating oil constitutes a critical part in the insulation of high voltage apparatus such as transformer. This paper presents an experimental investigation on transformer oil dynamic breakdown characteristics when subjected to AC voltage. Breakdown tests were carried out on mineral oil samples using a sphere-sphere electrode test cell for various gap lengths 1 mm,...
In this paper, we present an experimental study on the properties of mineral oils under AC breakdown conditions. Breakdown tests were carried out on mineral oil samples using a sphere-sphere electrode test cell for various gap lengths 1 mm, 2.5 mm and 5 mm and at different voltage speed ramps: 0.5 kV/s, 2 kV/s and 3.5 kV/s. The dynamic impedance of the mineral oil samples was determined from the instantaneous...
In this paper, we present the electrical and physic-chemical behaviours of oil in high voltage transformers, under thermal ageing. Continuous thermal ageing tests were made on transformer oil BORAK22 during 5000 hours at two different temperatures 80degC and 120degC. Here, every 500 hours, the dielectric losses factor, the relative permittivity and the resistivity were measured. Other properties such...