The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A microfiltration-membrane-coupled bioreactor (MMB) on pilot scale was operated for 135 days to investigate its technical feasibility in urban wastewater reclamation. Different operation parameters such as sludge retention time from 5 to 30 days, hydraulic retention time from 3.75 to 7.5 h, and membrane flux from 50 to 100 L.m -2 .h -1 , were tested. The highest sludge concentration...
A 162-day pilot-scale operation for reclamation of urban wastewater was studied by using an ultrafiltration membrane bioreactor (UMBR). Performance of the UMBR was investigated with a sludge retention time (SRT) of 5, 15, and 30 days, a hydraulic retention time (HRT) of 5h, and membrane flux between 75 and 150lm -2 h -1 , respectively. It was observed that the highest sludge...