The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The fast response, high efficiency and long lifetime of superconducting magnetic energy storage (SMES) compared to other energy storage systems make it a preferable selection for energy storage solution for wind power generation. SMES has attracted many researchers to study its potential applications in power systems. This paper discusses a scheme of fuzzy logic controlled SMES to minimize the voltage...
This paper presents a novel method to placement of power quality monitors (PQMs) by using the multivariable regression (MVR) model, the Cp and Rp statistical indices. In this method initially, fault data in each bus is collected and then the correlation coefficient (CC) which show the relationship between buses during system disturbances are calculated to identify two or three buses with the highest...
This paper presents a smart power quality data a analyzer (S-PQDA) or power quality diagnosis software (PQDS) tool that performs power quality (PQ) diagnosis on the PQ disturbance data recorded by an online PQ monitoring system. The software tool enables power utility engineers to perform automatic PQ disturbance detection, classification and diagnosis of the disturbances. The PQDS also assists the...
Voltage sag is considered as one of the most common power quality problems. It may cause sensitive equipment to malfunction and process interruption. This paper presents the application of network reconfiguration and DSTATCOM to mitigate voltage sags in power distribution networks. The proposed method first reinforces the system voltage profile during voltage sag by network reconfiguration. Then DSTATCOMs...
Voltage sag and swell are the common problem for sensitive load. The impact range from load disruptions to substantial economic losses. The DVR is the best solution to protect the sensitive loads. This paper present a fast DVR with controller to compensate the short outage, reduced the harmonic distortion and transient voltage for balanced and unbalanced load. In-phase method with continues two vector...
Many of the electrical systems throughout the world are experiencing problems with aging insulation. When an insulation system fails, the results are usually catastrophic. Insulation failure can cause sustained interruption which can cause substantial financial loses due to lost production and damage to expensive equipment. These losses can amount to thousands of ringgit (RM) per hour. With the ability...
In most parts of the world, the quality of the electrical power has become a major concern for many electricity users especially the industrial customers. To the power utility, all power quality disturbances must be detected, classified and diagnosed accurately so that proper mitigation measures can be implemented. This paper presents the application of the S-transform and support vector machine (SVM)...
This paper presents the design and construction of voltage acceptability curves for fluorescent lighting systems. It is derived from mathematical representation of actual light output variations of fluorescent lamps (FLs) during voltage sags and a predefined malfunction criterion called the light standard. Light standard may be thought of a standard based on a minimum acceptable light output, below...
Voltage sags are an important power quality problem for which the dynamic voltage restorer (DVR) is known as an effective device to mitigate them. This paper presents a new control algorithm for dynamic voltage restorer (DVR) that mitigates voltage sag by low active power injection with short time delay. This work is based on two-vector control technique using 12 pulse inverter. A smooth control technique...
This paper focuses on a novel automatic software tool to locate three major power quality disturbances, i.e. voltage sag, transient and harmonic. The software tool developed is to locate the source of these disturbances relative to a monitoring point. The methods employed in the software only require the current and voltage data. For locating the source of voltage sag, the product of the RMS current...