The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The growing recent interest in wearable and mobile technologies has led to increased research efforts toward development of non-invasive glucose monitoring platforms. Continuous glucose monitoring addresses the limitations of finger-stick blood testing and provides the opportunity for optimal therapeutic interventions. This article reviews recent advances and challenges toward the development of non-invasive...
The objective of the present work is to demonstrate a rational way to prepare selective sorbents able to extract simultaneously several structural analogs. For this purpose the binding specificity of two hexapeptides computationally designed (VYWLVW and YYIGGF) versus four synthetic cannabinoids Naphthalen-1-yl-(1-pentylindol-3-yl)methanone (JWH 018), naphthalen-1-yl-(1-butylindol-3-yl)methanone (JWH...
A dynamic micromotor-based immunoassay, exemplified by cortisol detection, based on the use of tubular micromotors functionalized with a specific antibody is described. The use of antibody-functionalized micromotors offers huge acceleration of both direct and competitive cortisol immunoassays, along with greatly enhanced sensitivity of direct and competitive immunoassays. The dramatically improved...
This article demonstrates an example of a wearable chemical sensor based on a fingernail platform. Fingernails represent an attractive wearable platform, merging beauty products with chemical sensing, to enable monitoring of our surrounding environment. The new colorimetric pH fingernail sensor relies on coating artificial nails with a recognition layer consisted of pH indicators entrapped in a polyvinyl...
Single-stranded DNA (ssDNA) aptamers specific to streptomycin were screened and identified from a random oligonucleotides library by affinity magnetic beads-based SELEX. After eight rounds of selection, 16 ssDNA with different sequences were identified. Then the dissociation constants (K d ) of these ssDNA were determined and an aptamer (STR1) with highest affinity for streptomycin was identified...
The simultaneous determination of three nitro-containing compounds found in the majority of explosive mixtures, namely hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), 2,4,6-trinitrotoluene (TNT) and pentaerythritol tetranitrate (PETN), is demonstrated using both qualitative and quantitative approaches involving the coupling of electrochemical measurements and advanced chemometric data processing. Voltammetric...
While high storage stability of sequence-selective DNA biosensors is crucial towards their routine applications, commonly used electrochemical hybridization biosensors are characterized with limited storage stability. In this article we demonstrate that recently developed ternary thiolated monolayers impart dramatic improvement in the storage stability of DNA electrochemical biosensors. In particular,...
The development of a microneedle-based biosensor array for multiplexed in situ detection of exercise-induced metabolic acidosis, tumor microenvironment, and other variations in tissue chemistry is described. Simultaneous and selective amperometric detection of pH, glucose, and lactate over a range of physiologically relevant concentrations in complex media is demonstrated. Furthermore, materials modified...
The development of rapid, low-cost and reliable diagnostic methods is crucial for the identification and treatment of many diseases. Screen-printed gold electrodes (Au/SPEs), coated with a ternary monolayer interface, involving hexanedithiol (HDT), a specific thiolated capture probe (SHCP), and 6-mercapto-1 hexanol (MCH) (SHCP/HDT/MCH) are shown here to offer direct and sensitive detection of nucleic...
A cooperative effect of two biomarkers, α-amylase and lactate dehydrogenase, was used to analyze radiation-caused tissue damage in vitro in model solutions of human serum. The analytical system was based on the recently emerged biocomputing concept applying biocatalytic cascades for logic processing of biochemical input signals. The studied system resembled a Boolean NAND logic gate in which the change...
Digital biosensor systems analyzing biomarkers characteristic of liver injury (LI), soft tissue injury (STI) and abdominal trauma (ABT) were developed and optimized for their performance in serum solutions spiked with injury biomarkers in order to mimic real medical samples. The systems produced ‘Alert’-type optical output signals in the form of “YES-NO” separated by a threshold value. The new approach...
The influence of the bending-induced mechanical stress of flexible Nafion ® /GOx/carbon screen-printed electrodes (SPEs) upon the performance of such glucose biosensors has been examined. Surprisingly, such flexible enzyme/polymer-SPEs operate well following a severe bending-induced mechanical stress (including a 180° pinch), and actually display a substantial sensitivity enhancement following...
A new end-column ‘hybrid’ contactless conductivity detector for microchip capillary electrophoresis (CE) was developed. It is based on a “hybrid” arrangement where the receiving electrode is insulated by a thin layer of insulator and placed in the bulk solution of the detection reservoir of the chip, whereas the emitting electrode is in contact with the solution eluted from the channel outlet in a...
This paper demonstrates that a combined thermal and electrochemical conditioning step can greatly minimize electrode blocking. We detected 50ppm dopamine after a blocking step in 1000ppm gelatine solution. Only a treatment of the electrode at −1.5V and 61.5°C can reveal the voltammetric dopamine signals to 82%. The increase of the peak separation of the cyclic voltammograms obtained in 50ppm dopamine...
In this paper, we have critically evaluated the electrochemical behavior of the products of seven substrates of the enzyme label, alkaline phosphate, commonly used in electrochemical immunosensors. These products (and the corresponding substrates) include indigo carmine (3-indoyl phosphate), hydroquinone (hydroquinone diphosphate), 4-nitrophenol (4-nitrophenol phosphate), 4-aminophenol (p-aminophenyl...
Glucose biosensors are key components of closed-loop glycaemic control (insulin delivery) systems for effective management of diabetes. By providing a fast return of the analytical information in a timely fashion, such sensors offer direct and reliable assessment of rapid changes in the glucose level, as desired for making optimal and timely therapeutic interventions in cases of hypo- and hyperglycemia...
We demonstrate that the selectivity of microchip electrophoresis separations is greatly improved by the presence of organically modified silica (Ormosil) sols in the run buffer. A negatively-charged N-(trimethoxysilylpropyl)ethylenediamine triacetic-acid (TETT)-based sol is used for improving the selectivity between nitroaromatic explosives and a methyltrimethoxysilane (MTMOS)-based sol is employed...
An electrochemical sensing platform was developed based on the magnetic loading of carbon nanotube (CNT)/nano-Fe 3 O 4 composite on electrodes. To demonstrate the concept, nano-Fe 3 O 4 was deposited by the chemical coprecipitation of Fe 2+ and Fe 3+ in the presence of CNTs in an alkaline solution. The resulting magnetic nanocomposite brings new capabilities...
A microchip capillary electrophoresis (CE)–amperometric detection (AD) system has been fabricated by integrating a two-dimensionally adjustable CE microchip and an amperometric detection cell containing a one-dimensionally adjustable disc detection electrode in a Plexiglas holder. It facilitates the precise three-dimensional alignment between the channel outlet and the detection electrode without...
This paper reports on a microfluidic device for the flow-injection/electrochemistry analysis of nitroaromatic explosive. The response is very fast (150assays/h), highly sensitive (detection limit 7.0μgL −1 ), reproducible and stable (R.S.D.=2.0%; n=30) and linear (over 20–100μgL −1 range). Relevant experimental parameters have been optimized. The new microsystem offers great promise...