The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Arsenic, one of the main environmental pollutants and potent natural poison, is a chemical element that is spread throughout the Earth's crust. It is well known that the toxicity of arsenic is highly dependent on its chemical forms. Generally, the inorganic species are more toxic than its organics forms, and As(III) is 60 times more toxic than As(V). In environmental waters, arsenic exists predominantly...
A green and simple method has been proposed in this work for the simultaneous determination of V, Ni and Fe in fuel ash samples by solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry (SS HR CS GFAAS). The application of fast programs in combination with direct solid sampling allows eliminating pretreatment steps, involving minimal manipulation of sample...
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been revealed as a convenient technique for trace elemental imaging in tissue sections, providing elemental 2D distribution at a quantitative level. For quantification purposes, in the last years several approaches have been proposed in the literature such as the use of CRMs or matrix matched standards. The use of Isotope...
This work showed a flow system designed with solenoid valves for preconcentration of fluoride using SPADNS method in water samples. The analyte was preconcentrated in a mini-column coated with Layered Double Hydroxides (LDH) used as adsorbent. Then, the fluoride ions were eluted with 0.5molL−1 sodium hydroxide and determined by spectrophotometry. The variables that affect the system such adsorbent...
The main limitations of lipidomics analysis are the chemical complexity of the lipids, the range of concentrations at which they exist, and the variety of samples usually analyzed. These limitations particularly affect the characterization of polar lipids owing to the interference of neutral lipids, essentially acylglycerides, which are at high concentration and suppress ionization of low concentrated...
Sweat is a promising biofluid scarcely used in clinical analysis despite its non-invasive sampling. A more frequent clinical use of sweat requires to know its whole composition, especially concerning to non-polar compounds, and the development of analytical strategies for its characterization. The aim of the present study was to compare different sample preparation strategies to maximize the detection...
A facile hydrothermal process was used to prepare MnCoxOy nanoparticles (NPs) in alkaline medium (pH~10.5) at room temperature. The NPs were characterized by Fourier-transform infrared spectroscopy (FTIR), ultraviolet visible spectroscopy (UV/vis), field emission scanning electron microscopy (FESEM), X-ray photoelectron spectroscopy (XPS), energy-dispersive X-ray spectroscopy (EDS), and powder X-ray...
In the present work, for the first time a systematic study was performed using an infrared camera and scanning electron microscopy (SEM) coupled to energy dispersive X-ray spectrometry (EDS) to evaluate the mechanisms involved in microwave-induced combustion method, which has been extensively used for sample preparation. Cellulose and glass fiber discs, wetted with the igniter solution (6molL−1 NH...
Construction of highly efficient toxic chemical sensors is the key approach for the determination of carcinogenic chemicals in the environment and ecosystem. We report here, an efficient acetone chemical sensor based on the analytical performances such as sensitivity, lower-detection limit, reproducibility, and good linearity. The proposed acetone-detecting electrode was introduced by the implementation...
A calibration strategy using porous nylon disks and reference solutions is proposed for the first time for matrix matching and determination of As, Ba, Cd, Cr, Pb, Sr and Zn in polymers by laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS). Polymer samples commonly used in contact with food were analyzed. The procedure consists on the use of porous nylon disks as support for a...
Middle and near infrared (MIR and NIR) were employed to determine organic carbon (OC) and total nitrogen (TN) in different soil organic amendments including wastes, composts and mixtures of composts and organic wastes. Prediction models based on partial least squares (PLS) regression from the spectra of untreated samples were built. Different spectra preprocessing strategies were adopted and the best...
In this work, a method for sample preparation of high-purity polyimide was proposed for halogens and sulfur determination by ion chromatography (IC) with conductivity detection and, alternatively, by inductively coupled plasma mass spectrometry (ICP-MS). A relatively high polyimide mass (600mg) was completely digested by microwave-induced combustion (MIC) using 20bar of O2 and 50mmolL−1 NH4OH as absorbing...
A new chelating sorbent which employs magnetic nanoparticles (MNPs) functionalized with 1,5-bis(di-2-pyridil)methylene thiocarbohydrazide (DPTH-MNPs) was synthetized and characterized. The aim of the synthesis of this material was to develop fast and simple methods for analysis of trace amounts of metal ions present in biological and environmental samples combining on-line magnetic solid phase microextraction...
Middle and near infrared (MIR and NIR) were applied to determine the total phenolic compounds (TPC) content in compost samples based on models built by using partial least squares (PLS) regression. The multiplicative scatter correction, standard normal variate and first derivative were employed as spectra pretreatment, and the number of latent variable were optimized by leave-one-out cross-validation...
In this work, a method for poly(vinyl chloride) (PVC) analysis by inductively coupled plasma optical emission spectrometry (ICP-OES) was developed. Samples were digested by microwave-induced combustion (MIC) and thirteen elements (Ba, Cd, Co, Cu, Fe, Mg, Mn, Mo, Ni, Pb, Sr, V and Zn) were determined by ICP-OES. Operational conditions of MIC were investigated allowing quantitative determination of...
This paper reports the first application of the silica based mesoporous material MCM-41 as a sorbent in solid phase extraction, to pre-concentrate pharmaceuticals of very different polarity (atenolol, nadolol, pindolol, timolol, bisoprolol, metoprolol, betaxolol, ketoprofen, naproxen, ibuprofen, diclofenac, tolfenamic acid, flufenamic acid and meclofenamic acid) in surface waters. The analytes were...
Estrogens circulate at concentrations less than 20pg/mL in men and postmenopausal women, presenting analytical challenges. Quantitation by immunoassay is unreliable at these low concentrations. Liquid chromatography tandem mass spectrometry (LC–MS/MS) offers greater specificity and sometimes greater sensitivity, but ionization of estrogens is inefficient. Introduction of charged moieties may enhance...
Silver migration from a commercial baby feeding bottle and a food box containing AgNPs, as confirmed by SEM-EDX analysis, was evaluated using food simulant solutions [i.e., water, 3% (v/v) acetic acid, and 10% and 90% (v/v) ethanol]. Silver release was investigated at temperatures in the 20–70°C range using contact times of up to 10 days. Migration of silver from the food box was in all cases 2 to...
The goal of this work is to emphasize the reliability of the thermal desorption technique in identifying mercury species. The analysis of mercury species in solids is essential for assessing the risk of disposal or re-use of mercury-contaminated materials. This study evaluates the accuracy and reliability of thermal desorption as a technique for identifying mercury species by means of different thermo-desorption...
A rapid, cost effective and environmentally friendly extraction method, based on dispersive liquid–liquid microextraction (DLLME) was developed for the determination of six tetracyclines in meat destined for human consumption. Meat extracts were analysed for tetracyclines using liquid chromatography tandem mass spectrometry (LC–MS/MS), a sensitive and selective analytical technique. Various factors...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.