The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Presented work focuses on detecting a single hard fault in analog electronic circuit in AC domain. The combined approach to analog circuit fault test frequency selection is proposed. Reduction of a fault dictionary size is the main goal of the method. It is achieved by the use of heuristic algorithm and modified fitness function. Simulated annealing as a search engine and fuzzy system as a fitness...
This paper discusses the optimization of input source frequencies to obtain the highest detection and location rate of a circuit under test. The minimum number of frequencies for distinguishes between fault and fault free elements are desired. We briefly describe the basic concepts of simulated annealing method and fuzzy evaluation (fitness) system. Presented application shows how to code the optimization...