The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The life cycle assessment of a grid‐connected, parking integrated, 222 kWp cadmium telluride photovoltaic system has been performed. The system was built at the University of Murcia and has been monitored for 2.5 years (sampling data every 5 min). The detailed material inventory, the energy embedded in the system, the energy payback time, and the energy return factor of the facility have been obtained...